{"version":1,"kind":"Article","sha256":"","slug":"555","location":"","dependencies":[],"doi":"10.54294/fiutzm","frontmatter":{"title":"Predicting implant stability: in vitro validation in artificial bone","abstract":"Primary stability of osseointegrated implants is necessary for short and long-term success of the treatment. This paper presents a method to help clinicians preoperatively assess this primary implant stability. The method combines a planning software with a in-house finite element solver. Once the clinician has chosen a position for the implant on the planning tool, a finite element analysis is automatically started and calculates the mechanical stability of the implant at this position. The process is designed to be as simple and fast as possible for an efficient clinical use. Mechanical testing material was used to validate the stability measured by the software. The novel tool presented here leads the way to a new generation of intelligent computer-assisted tools able to give a priori indication on the life span of the implant.","license":"You are licensing your work to Kitware Inc. under the\nCreative Commons Attribution License Version 3.0.\n\nKitware Inc. agrees to the following:\n\nKitware is free\n * to copy, distribute, display, and perform the work\n * to make derivative works\n * to make commercial use of the work\n\nUnder the following conditions:\n\\\"by Attribution\\\" - Kitware must attribute the work in the manner specified by the author or licensor.\n\n * For any reuse or distribution, they must make clear to others the license terms of this work.\n * Any of these conditions can be waived if they get permission from the copyright holder.\n\nYour fair use and other rights are in no way affected by the above.\n\nThis is a human-readable summary of the Legal Code (the full license) available at\nhttp://creativecommons.org/licenses/by/3.0/legalcode","keywords":["finite element","osseointegration","planning","implant"],"authors":[{"name":"Bardyn, Thibaut","email":"thibaut.bardyn@memcenter.unibe.ch","affiliations":["MEM Research Center - University of Bern"],"corresponding":true}],"date_submitted":"2008-05-21T20:17:18Z","external_publication_id":555,"revision_cids":["bafkreiaj4cyqccdkg2ej3qbb6s73okzr47ltlp7dr66k6qfbvtv65ppr7u"]},"mdast":{"type":"root"},"downloads":[{"url":"https://ipfs.desci.com/ipfs/bafkreidfu7326akyq25nqxbk2frevuh2kgqahn5ct5smobozeehymr6lru","title":"root/insight-journal-metadata.json","filename":"insight-journal-metadata.json","extra":{"size_bytes":12059,"type":"file"}},{"url":"https://ipfs.desci.com/ipfs/bafkreicgrfqitoyrmcllkwiljxbdnt22e3r3wlgrlgr7nmd7dmdqys7n2y","title":"root/reviews.md","filename":"reviews.md","extra":{"size_bytes":5690,"type":"file"}},{"url":"https://dweb.link/ipfs/bafybeieih4ccwd5ctzio2hegqak3swiijv3vfwi7lzz464rolv6zpv3f5m","title":"root/article.pdf","filename":"article.pdf","extra":{"size_bytes":1542466,"type":"file"}}],"references":{"cite":{"order":["ref1","ref2","ref3","ref4","ref5","ref6","ref7","ref8","ref9","ref10","ref11","ref12"]},"data":{"ref1":{"label":"ref1","enumerator":"1","html":"and its experimental background+J.Prosthet.Dent.+1983+P.I.Branemark. Osseointegration"},"ref2":{"label":"ref2","enumerator":"2","url":"https://doi.org/10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k","html":"Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature+J.Biomed.Mater.Res.+1998+S. Szmukler-Moncler"},"ref3":{"label":"ref3","enumerator":"3","html":"Assessment of implant stability as a prognostic determinant+Int.J.Prosthodont.+1998+N. Meredith"},"ref4":{"label":"ref4","enumerator":"4","url":"https://doi.org/10.1002/(sici)1522-712x(1995)1:1<53::aid-igs8>3.0.co;2-l","html":"Computer-assisted dental implant surgery using computed tomography+J.Image Guid.Surg.+1995+T. Fortin"},"ref5":{"label":"ref5","enumerator":"5","html":"Automated Finite Element Modeling of a Human Mandible With Dental Implants. The 6th Int'l Conf. in Central Europe on Comp. Graphics and Visualization '98 (WSCG '98)+1998+S. Fütterling"},"ref6":{"label":"ref6","enumerator":"6","url":"https://doi.org/10.1016/s0021-9290(01)00029-x","html":"Pre-clinical validation of a new partially cemented femoral prosthesis by synergetic use of numerical and experimental methods+J.Biomech.+2001+M. Viceconti"},"ref7":{"label":"ref7","enumerator":"7","url":"https://doi.org/10.1111/j.1600-0501.2004.01071.x","html":"A novel computational method for real-time preoperative assessment of primary dental implant stability+Clin.Oral Implants.Res.+2005+S. Olsen"},"ref8":{"label":"ref8","enumerator":"8","url":"https://doi.org/10.2106/00004623-197759070-00021","html":"The compressive behavior of bone as a twophase porous structure+J.Bone Joint Surg+1977+D.R. Carter+W. C."},"ref9":{"label":"ref9","enumerator":"9","url":"https://doi.org/10.1137/1034004","html":"The multifrontal method for sparse matrix solution: theory and practice+SIAM Review+1992+J.W.H. Liu"},"ref10":{"label":"ref10","enumerator":"10","html":"TAUCS - A library of sparse linear solvers+S. Toledo+D. Rotkin+V."},"ref11":{"label":"ref11","enumerator":"11","url":"https://doi.org/10.1016/j.clinbiomech.2005.12.020","html":"Experimental evaluation of the holding power/stiffness of the self-tapping bone screws in normal and osteoporotic bone material+Clinical Biomechanics+2006+S. Battula"},"ref12":{"label":"ref12","enumerator":"12","url":"https://doi.org/10.1016/j.jbiomech.2006.04.007","html":"Artificial composite bone as a model of human trabecular bone: The implant-bone interface+J.Biomech.+2006+J.A. Grant"}}}}